FixedStopTouchProbeSettings

Configure up to three thresholds for fixed stop detection (Torque, Velocity, Lag). Enter #Default to use the axis default value, or #Ignore to disable a threshold. Typical detection criteria: combination of high torque, low velocity, and/or increasing lag.

Syntax

Definition:

TYPE FixedStopTouchProbeSettings :
STRUCT
    TorqueThreshold   : LREAL;
    VelocityThreshold : LREAL;
    LagThreshold      : LREAL;
END_STRUCT
END_TYPE

Parameters

Name

Type

Default

Description

TorqueThreshold

LREAL

#Default

Threshold for the actual motor torque. If the torque exceeds this value during evaluation, it contributes to a fixed stop decision. Enter #Ignore to disable this threshold.

VelocityThreshold

LREAL

#Default

Upper limit for the actual axis velocity during evaluation. Fixed stop detection is evaluated only while the absolute velocity is below this value. Enter #Ignore to disable this threshold.

LagThreshold

LREAL

#Default

Threshold for the position following error (command position minus actual position). If the absolute following error exceeds this value during evaluation, it contributes to a fixed stop decision. Enter #Ignore to disable this threshold.

Version information

  • TwinCAT Standard >= v3.1.4026.23.1
  • TF5500 MC3 Base >= v4.0.6