CamCharacteristics
Computed characteristics of a cam table describing its motion profile properties.
Syntax
Definition:
TYPE CamCharacteristics :
STRUCT
NominalMasterVelocity : LREAL;
StartPoint : CamProfilePoint;
EndPoint : CamProfilePoint;
PointAtMinSlavePosition : CamProfilePoint;
PointAtMinSlaveVelocity : CamProfilePoint;
PointAtMinSlaveAcceleration : CamProfilePoint;
PointAtMinSlaveJerk : CamProfilePoint;
PointAtMaxSlavePosition : CamProfilePoint;
PointAtMaxSlaveVelocity : CamProfilePoint;
PointAtMaxSlaveAcceleration : CamProfilePoint;
PointAtMaxSlaveJerk : CamProfilePoint;
SlaveMeanAbsoluteVelocity : LREAL;
SlaveEffectiveAcceleration : LREAL;
Oid : OTCID;
NumberOfPoints : UDINT;
NumberOfActivePoints : UDINT;
NumberOfActiveSegments : UDINT;
IsValid : BOOL;
IsPeriodic : BOOL;
MinContinuityRequirement : EContinuity;
END_STRUCT
END_TYPEParameters
|
Name |
Type |
Default |
Description |
|---|---|---|---|
|
NominalMasterVelocity |
LREAL |
0.0 |
Nominal master velocity used to convert dimensionless slave values to time-based values. |
|
StartPoint |
|
Cam profile point at the start of the table. | |
|
EndPoint |
|
Cam profile point at the end of the table. | |
|
PointAtMinSlavePosition |
|
Cam profile point where the slave position reaches its minimum. | |
|
PointAtMinSlaveVelocity |
|
Cam profile point where the slave velocity reaches its minimum. | |
|
PointAtMinSlaveAcceleration |
|
Cam profile point where the slave acceleration reaches its minimum. | |
|
PointAtMinSlaveJerk |
|
Cam profile point where the slave jerk reaches its minimum. | |
|
PointAtMaxSlavePosition |
|
Cam profile point where the slave position reaches its maximum. | |
|
PointAtMaxSlaveVelocity |
|
Cam profile point where the slave velocity reaches its maximum. | |
|
PointAtMaxSlaveAcceleration |
|
Cam profile point where the slave acceleration reaches its maximum. | |
|
PointAtMaxSlaveJerk |
|
Cam profile point where the slave jerk reaches its maximum. | |
|
SlaveMeanAbsoluteVelocity |
LREAL |
0.0 |
Mean absolute velocity of the slave over the entire cam table range. |
|
SlaveEffectiveAcceleration |
LREAL |
0.0 |
RMS (effective) acceleration of the slave over the entire cam table range. |
|
Oid |
OTCID |
0 |
Object ID of the cam table these characteristics belong to. |
|
NumberOfPoints |
UDINT |
0 |
Total number of profile points in the cam table. |
|
NumberOfActivePoints |
UDINT |
0 |
Number of non-ignored profile points in the cam table. |
|
NumberOfActiveSegments |
UDINT |
0 |
Number of active interpolation segments between the profile points. |
|
IsValid |
BOOL |
false |
TRUE if the characteristics have been computed successfully. |
|
IsPeriodic |
BOOL |
false |
TRUE if the cam table is periodic (start and end boundary conditions match). |
|
MinContinuityRequirement |
EContinuity |
PositionVelocityAcceleration |
Minimum continuity level required for smooth operation of the cam table. |