Init Parameter

Scaling

Name

Default value

Unit

Type

Velocity Scaling Numerator to Hardware

1.0

INC/([PosUnit]/s)

LREAL

Velocity Scaling Denominator to Hardware

1.0

 

LREAL

Direction Inverted

FALSE

 

BOOL

Output Zero Offset

0.0

%

LREAL

Velocity Scaling Numerator to Hardware

Velocity Scaling Numerator To Hardware is used to calculate the analog output value based on the velocity setpoint.

Velocity Scaling Denominator to Hardware

Velocity Scaling Denominator To Hardware is used to calculate the analog output value based on the velocity setpoint.

Direction Inverted

The Direction Inverted parameter can reverse the counting direction of the encoder or drive:

WARNING

Risk of injury from unexpected movements

If the counting direction of the encoder and the motor polarity do not match, the axis will perform unexpected movements.

  • When commissioning the system, make sure that the drive's direction of rotation is set correctly.
  • Always maintain a safe distance.

Output Zero Offset

Output Zero Offset indicates the output at zero velocity as a percentage of the maximum output range (+-32767 for analog drives).

Connection

Name

Default value

Unit

Type

AMS address

0.0.0.0.0.0:0

 

 

 

.netId

0.0.0.0.0.0

 

AMSNETID

 

.port

0x0000

 

WORD

Channel Number

0

 

UDINT

EtherCAT Slave Oid

00000000

 

OTCID

AMS address

Information about the address of the assigned hardware drive (read-only); no manual configuration is required. It is used for communication purposes.

Channel Number

Information about the channel number of the assigned hardware drive (read-only); no manual configuration is required. It is used for communication purposes.

EtherCAT Slave Oid

Object ID of the EtherCAT slave.

Dead Time Compensation

A requirement for high-precision conversion of positions into times and vice versa is precise dead time compensation of the axes.

Name

Default value

Unit

Type

Dead Time Compensation

None

 

MC.EDeadTimeCompensationMode

 

Additional Time Shift to Hardware

0.0

ms

LREAL

Dead Time Compensation

Specify how the compensated setpoint and actual value should be calculated. The dead time is automatically determined during EtherCAT initialization.

Dead Time Compensation to Hardware

Time required to adjust the automatically calculated dead time for setpoint compensation.