Link a PLC to an axis object

An axis object has been created;
see Create an axis object.
A PLC project containing an instance of Tc3_Mc3Ptp.AXIS_REF has been created.
1. Build the PLC project.
The axis instance of the Tc3_Mc3Ptp.AXIS_REF should now be displayed under the PLC instances in the Solution Explorer tree.
Link a PLC to an axis object 1:
2. Link the PLC instance of the Tc3_Mc3Ptp.AXIS_REF to the MC3 axis instance (steps 1–5).
Link a PLC to an axis object 2:
The axis is now linked to the PLC.
The text field next to the Link to PLC… button displays the linked instance of AXIS_REF in the PLC.
In the configuration tree in Solution Explorer, a linked variable from the cyclic interface is indicated by a blue or white icon.
Link a PLC to an axis object 3:
3. Activate the TwinCAT project.