Online Parameter tab

The following online parameters are available:

Monitoring

Name

Unit

Type

Minimum Position Lag

[PosUnit]

LREAL

Maximum Position Lag

[PosUnit]

LREAL

Trigger Minimum/Maximum Position Lag Reset

 

Trigger Minimum/Maximum Position Lag Reset

Minimum Position Lag

This read-only online parameter displays the minimum detected position lag for informational purposes.

Maximum Position Lag

This read-only online parameter displays the maximum detected position lag for informational purposes.

Trigger Minimum/Maximum Position Lag Reset

A rising edge at this parameter input resets the stored minimum and maximum position lags.

Additional Error Event Information

Name

Unit

Type

Originating Error Event Sender ID

 

OTCID

Original Error Id

 

HRESULT

Originating Error Event Sender ID

If a subsequent error occurs - for example, due to coupling - this parameter displays the object ID of the axis from which the error originated.

Original Error Id

If a subsequent error occurs - for example, due to a coupling - this online parameter displays the original error number.

Override

Name

Unit

Type

Velocity Override Factor

 

LREAL

Velocity Override Factor

The current velocity override for the axis is displayed here.