MC_ActivateTrack
This function block activates a track as a reference system, which can then be used in various motion function blocks for positioning. The XTS track object must be created under the XTS Processing Unit and is then selected via the Object Id. The XTS tracks are configured via the XTS Configurator (see XTS documentation for more information). ObjectID 0 can be used to reactivate the absolute reference system.
VAR_INPUT
VAR_INPUT
Execute : BOOL;
TrackId : OTCID;
END_VAR
Name | Type | Description |
---|---|---|
Execute | BOOL | The command is triggered by a rising edge at this input. |
TrackId | OTCID | Object ID of the active track reference system. |
VAR_IN_OUT
VAR_IN_OUT
Axis : AXIS_REF;
END_VAR
Name | Type | Description |
---|---|---|
Axis | AXIS_REF | Reference to an axis (see AXIS_REF). |
VAR_OUTPUT
VAR_OUTPUT
Done : BOOL;
Busy : BOOL;
Error : BOOL;
ErrorId : UDINT;
END_VAR
Name | Type | Description |
---|---|---|
Done | BOOL | This output becomes |
Busy | BOOL | This output becomes |
Error | BOOL | This output becomes |
ErrorId | UDINT | Contains the command-specific error code of the last executed command. Details of the error code can be found in the ADS error documentation or in the NC error documentation (error codes 0x4nnn and 0x8nnn). |
Requirements
Development environment | Target platform | PLC libraries to include |
---|---|---|
TwinCAT V3.1.4024.7 TF5400 Advanced Motion Pack V3.1.10.1 | PC or CX (x86 or x64) | Tc3_McCollisionAvoidance, Tc3_McCoordinatedMotion, Tc2_MC2 |