Programming example
Programming Example
Calculation cycle
; creation of return variables
#VAR
V.CYC.SysRetDirVectorX
V.CYC.SysRetDirVectorY
V.CYC.SysRetDirVectorZ
V.CYC.SysRetSupVectorX
V.CYC.SysRetSupVectorY
V.CYC.SysRetSupVectorZ
V.CYC.SysRetVariance
#ENDVAR
; calc line of X-axis from points
L CYCLE [NAME=SysCalcLine.ecy \
@P50 = 0 @P60 = 0 @P70 = 0 \
@P51 = 1 @P61 = 0 @P71 = 0 \
@P52 = 2 @P62 = 0 @P72 = 0 \
]
#FILE NAME[MSG="SysCalcLineResult.txt" ]
#MSG SAVE ["Direction X = %f", V.CYC.SysRetDirVectorX]
#MSG SAVE ["Direction Y = %f", V.CYC.SysRetDirVectorY]
#MSG SAVE ["Direction Z = %f", V.CYC.SysRetDirVectorZ]
#MSG SAVE ["Point on Line X = %f", V.CYC.SysRetSupVectorX]
#MSG SAVE ["Point on Line Y = %f", V.CYC.SysRetSupVectorY]
#MSG SAVE ["Point on Line Z = %f", V.CYC.SysRetSupVectorZ]
#MSG SAVE ["Variance = %f", V.CYC.SysRetVariance ]
M30