Parameterisation

The section below describes the parameterisation of position data.

In addition, the parameters of the drilling cycle must also be specified when the cycle is called (see Programming example). The actual drilling cycle is parameterised as described in the cycle documentation:

The position parameters here refer to the currently active tool coordinate system (before cycle call).

Required input parameters

Input parameters

Description

@P100

Reference cycle as character string

@P104

Distance between positions in X (incremental)

@P107

Number of positions

Optional input parameters

Input parameters

Description

@P101

Coordinate in X of the first position (absolute)

Default value = current position in X

@P102

Coordinate in Y of the first position (absolute)

Default value = current position in Y

@P109

Rotation of pattern in relation to the X axis (in degrees)

Default value = 0

It is recommended to use the Syntax check to verify whether the input parameters are correctly assigned.