Parameterisation
Required input parameters:
Input parameters | Description |
@P1 | Reference plane (absolute) |
@P2 | Retraction plane (absolute) |
@P3 | Safety clearance in Z (relative to reference plane/machining height) |
@P4 | Depth (relative to reference plane) |
@P5 | Maximum infeed in Z |
@P50 | Identification number of the path contour |
Optional input parameters:
Input parameters | Description |
@P6 | Infeed in XY to remove the additional roughing allowance (@P95). The default value is the current tool radius (Maximum V.G.WZ_AKT.R is recommended to avoid residual material) |
@P15 | Finishing allowance at base Default value = 0 |
@P16 | Finishing allowance at edge (only when tool radius compensation is active @P75) Default value = 0 |
@P20 | Feed rate for roughing for milling in the XY plane (specified in mm/min, inch/min) |
@P21 | Feed rate for infeed in Z (values in mm/min, inch/min) |
@P22 | Feed rate for finishing for milling in the XY plane (specified in mm/min, inch/min) The default value is the feed rate for roughing |
@P23 | Feed rate for finishing for infeed in Z (specified in mm/min, inch/min) The default value is the feed rate for finishing for milling in the XY plane |
@P25 | Spindle speed for finishing |
@P30 | Machining direction "ClimbMilling" or 0: Down milling (default) "UpCutMilling" or 1: Up milling |
@P31 | Machining mode: "Roughing" or 1: Roughing "Finishing" or 2: Finishing "Roughing+Finishing" or 3: Roughing and finishing (default value) |
@P32 | Feed mode in Z 1: Vertical at start and end of machining movement (default value) 2: In space during approach and withdrawal movements |
@P75 | Tool radius compensation "TrcOff" or 0: Off (default value) "TrcLeft" or 1: Left of path contour "TrcRight" or 2: Right of path contour |
@P90 | Approach movement "MotionNone" or 0: No approach movement (default value) "MotionLinear" or 1: Straight line: "MotionQuarterCircle" or 2: Quadrant "MotionHalfCircle" or 3: Semicircle |
@P91 | Length (straight line) / radius (quadrant/semicircle) of the approach movement Default value = 0 |
@P92 | Withdrawal movement "MotionNone" or 0: No withdrawal movement (default value) "MotionLinear" or 1: Straight line: "MotionQuarterCircle" or 2: Quadrant "MotionHalfCircle" or 3: Semicircle |
@P93 | Length (straight line) / radius (quadrant/semicircle) of the withdrawal movement Default value = 0 |
@P95 | Additional roughing allowance (results in removal of the contour path multiple times) Default value = 0 |
@P135 | Maximum infeed in XY for edge finishing The default value is the current tool radius |
Most of the parameter functions which mainly refer to the Z axis are displayed in the graphic below:
It is recommended to use the Syntax check to verify whether the input parameters are correctly assigned.
