Programming example
Programming Example
Mill contour pocket
This example describes milling of a contour pocket defined in the NC program. This results in the following cycle call:
T8 D8 ( tool data )
M6 ( tool change )
G90 G54 M03 S6000 F5000 ( technology data )
G00 Z100 ( go to z start position )
G00 X0 Y0 ( go to start position )
#VAR
V.L.SurfacePosition = 0 ( Z position of workpiece surface )
V.L.RetractionPlane = 100 ( Z position of retraction plane )
V.L.SafetyClearance = 5 ( relative value of safety clearance )
V.L.DepthOfPocket = 20 ( depth of pocket )
V.L.MaxIncrementZ = V.L.DepthOfPocket / 2 ( maximum infeed in Z )
V.L.MaxIncrementXY = V.G.WZ_AKT.R*0.9 ( maximum infeed in XY )
V.L.FeedRateZ = 150 ( plunging feedrate )
V.L.ContourID = 1 (identification number pocket contour)
#ENDVAR
; contour definition:
#CONTOUR BEGIN[ID = 1]
G1 G90 X90 Y20
G1 G91 Y40
G1 G91 X-20
G1 G90 X50 Y80
G1 X30 Y60
G161 G03 X30 Y20 I30 J40
G1 X90
#CONTOUR END
G0 ZV.L.RetractionPlane
; polynomial contouring for smooth movements
#CONTOUR MODE [DEV, PATH_DEV = V.G.WZ_AKT.R / 100]
G261
L CYCLE [NAME = SysMillContourPocket.ecy \
@P1 = V.L.SurfacePosition \
@P2 = V.L.RetractionPlane \
@P3 = V.L.SafetyClearance \
@P4 = V.L.DepthOfPocket \
@P5 = V.L.MaxIncrementZ \
@P6 = V.L.MaxIncrementXY \
@P21 = V.L.FeedRateZ \
@P31 = "Roughing" \
@P50 = V.L.ContourID \
]
G260
M30