Parameters for AB and BV orientation head

Parameters are defined under the ID 93 of the kinematic offsets (P-CHAN-00263 and P-CHAN-00094).

The parameters in the AB and BV configurations only differ in the assignment of HD13.

HD offset

param[i]

Description

Unit

HD1

0

Z axis offset to the tool fixing point

1.0 E-4 mm

HD2

1

X axis offset to the tool fixing point

1.0 E-4 mm

HD3

2

Y axis offset to the tool fixing point

1.0 E-4 mm

HD4

3

X offset rotation point A axis to. rotation point B axis

1.0 E-4 mm

HD5

4

Y axis offset rotation point A axis to rotation point B axis

1.0 E-4 mm

HD6

5

Z axis offset rotation point A axis to rotation point B axis

1.0 E-4 mm

HD7

6

X axis offset zero point to rotation point A axis

1.0 E-4 mm

HD8

7

Y axis offset zero point to rotation point A axis

1.0 E-4 mm

HD9

8

Z axis offset zero point to rotation point A axis

1.0 E-4 mm

HD10

9

n.a.

 

HD11

10

n.a.

 

HD12

11

Angle offset U/V axis

1.0 E-4°

HD13

12

Orientation head, sequence of rotary axes
0 : AB
10: BV

[ - ]

HD14

13

PCS angle programming
0: same as orientation head
1: CA

[ - ]

HD15

14

Rotation direction AM,
, 0: math positive
1: math negative

[ - ]

HD16

15

Rotation direction BM
0: math positive
1: math negative

[ - ]

HD17

16

Angle offset AM

1.0 E-4°

HD18

17

Angle offset BM

1.0 E-4°

HD19

18

n.a.

 

HD20

19

n.a.

 

HD21

20

n.a.

 

HD22

21

n.a.

 

HD23

22

n.a.

 

HD24

23

Z offset of rotary axis U to machine zero point (MNP)

1.0 E-4 mm

HD25

24

X offset of rotary axis U to machine zero point

1.0 E-4 mm

HD26

25

Y offset of rotary axis U to machine zero point

1.0 E-4 mm

HD27

26

-

 

HD28

27

Angle offset of workpiece clamp position

1.0 E-4°

The general description is contained in the channel parameter list under P-CHAN-00263 and P-CHAN-00094.