Parameters for CA orientation head

Parameters are defined under the ID 90 of the kinematic offsets (P-CHAN-00263 and P-CHAN-00094).

HD offset

param[i]

Description

Unit

HD1

0

Z axis offset to the tool fixing point

1.0 E-4 mm

HD2

1

X axis offset to the tool fixing point

1.0 E-4 mm

HD3

2

Y axis offset to the tool fixing point

1.0 E-4 mm

HD4

3

X axis offset rotation point C axis to rotation point A axis

1.0 E-4 mm

HD5

4

Y axis offset rotation point C axis to rotation point A axis

1.0 E-4 mm

HD6

5

Z axis offset rotation point C axis to rotation point A axis

1.0 E-4 mm

HD7

6

X offset reference point to rotation point C axis

1.0 E-4 mm

HD8

7

Y offset reference point to rotation point C axis

1.0 E-4 mm

HD9

8

Z offset reference point to rotation point C axis

1.0 E-4 mm

HD10

9

n.a.

 

HD11

10

n.a.

 

HD12

11

Angle offset U/V axis

1.0 E-4°

HD13

12

Orientation head, sequence of rotary axes
2: CA
4: CB

[ - ]

HD14

13

-

 

HD15

14

Rotation direction CM
0: math positive
1: math negative

[ - ]

HD16

15

Rotation direction AM
0: math positive
1: math negative

[ - ]

HD17

16

Angle offset CM

1.0 E-4°

HD18

17

Angle offset AM

1.0 E-4°

The general description is contained in the channel parameter list under P-CHAN-00263 and P-CHAN-00094.

Parameters for CA orientation head 1:
Parameters for CA orientation head