Round tube, projection (kinematic ID 78)

Parameters are defined under the ID 78 of the kinematic offsets (P-CHAN-00263 and P-CHAN-00094).

HD offset

param[i]

Description

Unit

HD1

0

Z offset tool fixing point - Tool carrier reference point

1.0 E-4 mm

HD2

1

X offset tool fixing point - Tool carrier reference point

1.0 E-4 mm

HD3

2

Y offset tool fixing point - Tool carrier reference point

1.0 E-4 mm

HD4

3

-

 

HD5

4

Z offset of rotary axis U to machine zero point

1.0 E-4 mm

HD6

5

X offset of rotary axis U to machine zero point

1.0 E-4 mm

HD7

6

Y offset of rotary axis U to machine zero point

1.0 E-4 mm

With regard to modulo calculation, the U axis is handled depending on the MDS setting in the axis.

The general description is contained in the channel parameter list under P-CHAN-00263 and P-CHAN-00094.

Round tube, projection (kinematic ID 78) 1:
Tube projection transformation kinematic offsets