Tube machining (#CYL ORI LATERAL)
![]() | The kinematic parameters in ID 90 must be set for this machining type. |
Syntax for selecting and parameterising, active as of the next motion block:
Syntax: |
#CYL ORI LATERAL [ AX1<axis_name> | AXNR1=.. AX2<axis_name> | AXNR2=.. RADIUS=.. ] |
AX1<axis_name> | Axis identifier of the first main axis (X or virtual linear axis U, flat projection) |
AXNR1=.. | Logical axis number of first main axis (X or virtual linear axis U, flat projection), positive integer |
AX2<axis_name> | Axis identifier of the second main axis (Y or virtual linear axis V, flat projection) |
AXNR2=.. | Logical axis number of the second main axis (Y or virtual linear axis V, flat projection), positive integer |
RADIUS=.. | Tube (bending) radius, [mm, inch] |
Syntax for deselection:
#CYL OFF |