Path example

Programming Example

Lateral surface transformation

;Lateral surface transformation
N30 #SLOPE [TYPE=STEP]
N40 G00 X0 Y0 Z100 U0
N50 #CYL [X, U, Z35]  ;Select lateral surface machining
N70 G01 G90 X0 U0 F5000
N80 G01 Z10 G90  F50000
N110 $FOR P2=1, 5, 1
N120  P3=P2*4
N130  P4=P3+2
N140  G01 G91 U-P3
N150          XP3
N160          U[2*P3]
N170          X-P3
N180 G90 U0
N190 G91 XP4
N190 $ENDFOR
N200 $FOR P2=1, 5, 1
N210  P3=P2*4
N220  P4=P3*2+2
N230  G90 G02 IP3
N240      G91 G01 XP4
N250 $ENDFOR
N290 #CYL OFF  ;Deselect lateral surface machining
M30
Path example 1:
X-U contour line projection