KERNELV_CHANNEL_STATE

Enumeration CNC_SIMU_CHANNEL_STATE describes the state of a CNC channel.

The state of a CNC channel is described by the following state diagram:

Symbol

Value

Meaning

KERNELV_STATE
_DESELECTED

1

Channel state is DESELECTED.

KERNELV_STATE
_SELECTED

2

Channel state is SELECTED.

KERNELV_STATE_READY

3

Channel state is READY.

KERNELV_STATE_ACTIVE

4

Channel state is ACTIVE, and an NC program is currently being executed.

KERNELV_STATE_HOLD

5

Channel state is HOLD. An NC program has been started and then stopped.

KERNELV_STATE_ERROR

6

Channel state is ERROR.

KERNELV_STATE
_SELECTING

7

Channel state is SELECTING.

KERNELV_STATE
_DESELECTING

8

Channel state is DESELECTING.

KERNELV_STATE
_PREPARING

9

Channel state is PREPARING.

KERNELV_STATE
_CLEARING

10

Channel state is CLEARING.

KERNELV_STATE
_STARTING

11

Channel state is STARTING. An NC program is currently being started.

KERNELV_STATE
_ABORTING

12

Channel state is ABORTING. An NC program is currently being aborted.

KERNELV_STATE
_STOPPING

13

Channel state is STOPPING. A running NC program is stopped.

KERNELV_STATE
_RESUMING

14

Channel state is RESUMING. A stopped NC program is resumed.

KERNELV_STATE
_RESETTING

15

Channel state is RESETTING. A reset is currently taking place.

KERNELV_CHANNEL_STATE 1:
State diagram of a CNC channel