kernelv_ch_get_techno_data()

Prototype

KERNELV_RETURN

kernelv_ch_get_techno_data(unsigned long int chanindex,
                                                KERNELV_TECHNO_DATA* technoData
                                                unsigned long int technoLength
                                                unsigned long int* returnLength);

Description

Returns the technology functions (M/H functions) acknowledged for the specified channel during the last call of kernelv_do_cycle().

Parameter

Name

Type

Meaning

chanIndex

unsigned long int

Channel index

technoData

KERNELV_TECHNO_DATA*

Pointer to the memory area to which the technology data is to be written.

technoLength

unsigned long int

Size of the provided memory area in bytes.

returnLength

unsigned long int*

Pointer to the memory area to which the actually returned bytes are to be written.

Return values

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_INVALID_CHAN

-1

The transferred channel index is higher than the number of configured channels -1.

ERR_CNC_NOT_INIT

-3

The simulation CNC kernel was not yet initialised.

ERR_CNC_RET_MEMORY

-4

The return value(s) does/do not fit into the memory provided. The number of bytes required is returned in the returnLength parameter.