kernelv_ch_get_status_singularity_avoidance()
Prototype
[ret, active] | ch_get_status_singularity_avoidance(vnck: ct.CDLL, channel_number: int) |
Description
Reads out the current activity status of singularity avoidance in the specified channel. Returns the activity status, i.e. whether the currently interpolated motion block should avoid a kinematic singularity.
Parameter
Name | Type | Meaning |
vnck | ctypes.CDLL | Instance of the loaded KernelV DLL. |
chan_number | int (unsigned) | Channel index of the channel from which the variable is to be read. |
Return values
Name | Type | Meaning |
ret | KERNELV_RETURN (int) | Return value of the native integrated C function. |
active | bool | Activity status |
KERNELV_RETURN
Symbol | Value | Meaning |
RET_FINISHED | 0 | The function was executed without error. |
ERR_INVALID_CHAN | -1 | The transferred channel index is higher than the number of configured channels -1. |
ERR_CNC_NOT_INIT | -3 | The simulation CNC kernel was not yet initialised. |