kernelv_ch_get_kin_trafo_active()
Prototype
[ret, active] | ch_get_kin_trafo_active(vnck: ctypes.CDLL, chan_index: int) |
Description
Returns whether a kinematic transformation is currently active. If no kinematic transformation is active, 0 is returned.
Parameter
Name | Type | Meaning |
vnck | ctypes.CDLL | Instance of the loaded KernelV DLL. |
chan_index | int (unsigned) | Channel index of the channel. |
Return values
Name | Type | Meaning |
ret | KERNELV_RETURN (int) | Return value of the native integrated C function. |
active | bool | Returns the status of the active kinematic transformation. |
KERNELV_RETURN
Symbol | Value | Meaning |
RET_FINISHED | 0 | The function was executed without error. |
ERR_INVALID_CHAN | -1 | The transferred channel index is higher than the number of configured channels -1. |
ERR_CNC_NOT_INIT | -3 | The simulation CNC kernel was not yet initialised. |