kernelv_ch_get_total_cs_rot_matrix()

Prototype

[ret, matrix

 

ch_get_total_cs_rot_matrix(vnck: ctypes.CDLL,

chan_index: int):

Description

Returns the rotation matrix generated by concatenating all active coordinate systems.

The rotation matrix, e.g. generated by the parameters ϕ1, ϕ2 ϕ3 of the NC command below is returned:

#CS DEF [CS1] [ <v1>,<v2>,<v3>,<ϕ1>,<ϕ2>,<ϕ3> ]

If no coordinate system is active, the standard matrix is returned.

Parameter

Name

Type

Meaning

vnck

ctypes.CDLL

Instance of the loaded KernelV DLL.

chan_index

int (unsigned)

Channel index of the channel.

Return values

Name

Type

Meaning

ret

KERNELV_RETURN (int)

Return value of the native integrated C function.

matrix

numpy.ndarray [tuple[int, int]]

Rotation matrix.

KERNELV_RETURN

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_INVALID_CHAN

-1

The transferred channel index is higher than the number of configured channels -1.

ERR_CNC_NOT_INIT

-3

The simulation CNC kernel was not yet initialised.

ERR_CNC_RET_MEMORY

-4

The return value(s) does/do not fit into the memory provided. In this case, the minimum size required for the return is returned in returnLength.