kernelv_program_error_get_file_name

Prototype

[ret, file_name, length]

program_error_get_file_name(vnck: ctypes.CDLL);

Description

Returns the file name of the active NC program.

If the program was started by specifying an absolute program name, the compete program name is returned.

If the CNC controller opened the NC program by using a search path, this function returns the file name specified at program start. The search path used can be requested by the function kernelv_program_error_get_path().

The function returns the number of returned bytes in returnLength, i.e. including the zero terminating the string.

If the memory provided by the calling application is too small for the string to be returned, the return value ERR_CNC_RET_MEMORY is returned In this case, the length parameter contains the size in bytes required to return the string.

Parameter

Name

Type

Meaning

vnck

ctypes.CDLL

Instance of the loaded KernelV DLL.

Return values

Name

Type

Meaning

ret

KERNELV_RETURN (int)

Return value of the native integrated C function.

file_name

str

Name of the file.

length

int (unsigned)

Actual length of the error message in bytes.

KERNELV_RETURN

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_CNC_RET_MEMORY

-4

The return value(s) does/do not fit into the memory provided. The number of bytes required is returned in the ‘length’ parameter.

ERR_CNC_NO_DATA

-28

The requested data is not available. There is no available NC program specific data relating to an CNC error.