kernelv_get_error_severity()

Prototype

int (unsigned)

get_error_severity(vnck: ctypes.CDLL );

Description

Returns the error remedy class of an error message previously read by kernelv_read_error(). If no error message was read or there is no current error message, the value -1 is returned.

Parameter

Name

Type

Meaning

vnck

ctypes.CDLL

Instance of the loaded KernelV DLL.

Return values

Type: int (signed)

-1 if there is no current error message; otherwise the error remedy class (see also [DIAG]).

Error remedy class

Internal error remedy

0

Error message acts as a warning; automatically an internal troubleshooting takes place.

2

Requires a complete reset of the NC channel.

5

Requires a complete reset of the NC channel.

6

Requires a repeated start-up of the CNC kernel.

7

Requires a repeated start-up of the entire NC kernel after switch-off.