kernelv_ch_get_override()

Prototype

[ret, override]

ch_get_override(vnck: ctypes.CDLL, chan_index: int);

Description

Reads the current override value for the channel.

Parameter

Name

Type

Meaning

vnck

ctypes.CDLL

Instance of the loaded KernelV DLL.

chan_index

int

Channel index of the channel whose override is to be read.

Return values

Name

Type

Meaning

ret

KERNELV_RETURN (int)

Return value of the native integrated C function.

override

int (unsigned)

The current override value is returned in 0.1%.

KERNELV_RETURN

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_INVALID_CHAN

-1

The transferred channel index is higher than the number of configured channels -1.

ERR_CNC_NOT_INIT

-3

The simulation CNC kernel was not yet initialised.