kernelv_ch_get_cs_count()

Prototype

KERNELV_RETURN

ChGetCsCount(

uint chanIndex,

out ushort count

);

Description

Returns the number of defined coordinate systems.

Even if no coordinate system is defined in the NC program, there is always a basic coordinate system at coordinate system stack level 0. Its rotation matrix is the standard matrix and its shift vector is the zero vector.

Parameter

Name

Type

Meaning

chanIndex

uint

Channel index of the channel.

count

out ushort

Returns the number of coordinate systems.

Return values

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_INVALID_CHAN

-1

The transferred channel index is higher than the number of configured channels -1.

ERR_CNC_NOT_INIT

-3

The simulation CNC kernel was not yet initialised.

ERR_READ_ERR

-26

An error occurred on reading data from the kernelv DLL.