kernelv_get_error_values()
Prototype
KERNELV_RETURN | GetErrorValues(out KERNELV_ERROR_VALUE[] values); |
Description
Returns the values output in an error message.
Before using this function, a check must first be made whether there is a current error by calling the function Read_error().
The values are returned in an array of structures of type KERNELV_ERROR_VALUE. The array size is KERNELV_ERROR_VALUE_COUNT.
If the returned array fails to fit in the memory provided, the return value ERR_CNC_RET_MEMORY is output.
Parameter
Name | Type | Meaning |
values | out KERNELV_ERROR_VALUE | Pointer to string for error message values. The calling application must provide the memory. |
Return values
Symbol | Value | Meaning |
RET_FINISHED | 0 | The function was executed without error. |
ERR_CNC_NOT_INIT | -3 | The simulation CNC kernel was not yet initialised. |
ERR_CNC_RET_MEMORY | -4 | The return value(s) does/do not fit into the memory provided. The number of bytes required is returned in the 'length’ parameter. |