kernelv_control_techno_func_duration()
Prototype
KERNELV_RETURN | ControlTechnoFncDuration(bool enable); |
Description
Activates or deactivates execution time simulation for technology functions.
By default, execution time simulation is off, i.e. technology functions are acknowledged immediately. When execution time simulation is active, acknowledgement of the technology functions is delayed to simulate their actual execution time.
The execution time can be set by means of the kernelv_ch_set_techno_func_duration() function or by means of entries in the channel parameter list (P-CHAN-00040, P-CHAN-00026).
If execution time simulation is deactivated while still unacknowledged technology functions are pending, they are acknowledged immediately regardless of the set execution time.
Parameter
Name | Type | Meaning |
enable | bool | If enable = true, the execution time simulation is activated. The value ‘false’ deactivates the execution time simulation. |
Return values
Symbol | Value | Meaning |
RET_FINISHED | 0 | The function was executed without error. |