kernelv_get_axis_channel_number()

Prototype

KERNELV_RETURN

GetAxisChannelNumber(out ushort [] chanNumbers);

Description

By configuration or by axis replacement commands during an NC program, an axis can be moved by different CNC channels. By means of this function, the number of the channel moving the respective axis can be queried.

The following relationship exists between the channel number and the channel index:

Channel index = channel number –1

Parameter

Name

Type

Meaning

chanNumbers

out ushort []

The channel numbers are returned.

Return values

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_CNC_NOT_INIT

-3

The simulation CNC kernel was not yet initialised.

ERR_CNC_RET_MEMORY

-4

The return value(s) does/do not fit into the memory provided. In this case, the required memory is returned in the returnSize parameter.