kernelv_ch_get_techno_data2()

Prototype

KERNELV_RETURN

ChGetTechnoData2(uint chanIndex, out List<KERNELV_TECHNO_DATA2> technoDataList);

Description

Returns the technology functions (M/H functions) acknowledged for the specified channel during the last call of kernelv_do_cycle().

Parameter

Name

Type

Meaning

chanIndex

uint

Channel index

technoDataList

out List<KERNELV_TECHNO_DATA2>

List of technology data structures received.

Return values

Symbol

Value

Meaning

RET_FINISHED

0

The function was executed without error.

ERR_INVALID_CHAN

-1

The transferred channel index is higher than the number of configured channels -1.

ERR_CNC_NOT_INIT

-3

The simulation CNC kernel was not yet initialised.

ERR_CNC_RET_MEMORY

-4

The return value(s) does/do not fit into the memory provided. The number of bytes required is returned in the returnLength parameter.