Parameterisation example

The required parameters of the axes concerned are listed below:

Axis 1

kopf.log_achs_name                   X
kopf.achs_nr                         1
kenngr.antr_typ                      4          ( P-AXIS-00020

Axis 2

kopf.log_achs_name                   Y
kopf.achs_nr                         2

Axis 3

kopf.log_achs_name                   Z
kopf.achs_nr                         3
kenngr.swe_pos                       550000     ( P-AXIS-00178
kenngr.swe_neg                       -550000    ( P-AXIS-00177
kenngr.antr_typ                      4          ( P-AXIS-00020

Axis 4

kopf.log_achs_name C
kopf.achs_nr 4

Spindle

kopf.log_achs_name                   S
kenngr.achs_typ                      4          ( type == 4 spindle
kenngr.measure.signal                PLC_FIRST_EVENT
conv_sync.is_master                  1
conv_sync.enable_filter              1
conv_sync.type_pos_filter            1
conv_sync.order_pos_filter           4
conv_sync.order_v_filter             10
conv_sync.order_post_v_filter        6
conv_sync.order_v_filter_dyn         10
conv_sync.delay_time                 17455

The required entries in the channel parameter list are as follows:

configuration.interpolator.function  FCT_DLM    ( P-CHAN-00650
conveyor_sync.log_number_master      5          ( P-CHAN-00362 - spindle
conveyor_sync.move_direction         0          ( P-CHAN-00363
conveyor_sync.x_virtual              1          ( P-CHAN-00364
conveyor_sync.sync_in_tolerance      100        ( P-CHAN-00365
conveyor_sync.hold_limit_vel_factor  950        ( P-CHAN-00366
conveyor_sync.hold_limit_tolerance   5.000e+004 ( P-CHAN-00367
conveyor_sync.cart_t0_shift_x        -10000000  ( P-CHAN-00368
conveyor_sync.cart_t0_shift_y        0          ( P-CHAN-00369
conveyor_sync.cart_t0_shift_z        0          ( P-CHAN-00370
conveyor_sync.cart_t0_rot_a          0          ( P-CHAN-00371
conveyor_sync.cart_t0_rot_b          0          ( P-CHAN-00372
conveyor_sync.cart_t0_rot_c          0          ( P-CHAN-00373
conveyor_sync.pos_limit              -1900000   ( P-CHAN-00374
log_number_tracking_axis             4          ( P-CHAN-0095