Axis parameters

P-AXIS-00001

Acceleration at machining feed (non-linear slope)

Description

The parameter represents the axis acceleration with increasing velocity.

Parameter

getriebe[i].slope_profil.a_beschl

Data type

UNS32

Data range

1 ≤ a_beschl ≤ P-AXIS-00008

Axis types

T, R

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in [PROG//G130/G131] in greater detail.

P-AXIS-00002

Deceleration at machining feed (non-linear slope)

Description

The parameter represents the axis deceleration with decreasing velocity.

Parameter

getriebe[i].slope_profil.a_brems

Data type

UNS32

Data range

1 ≤ a_brems ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in [PROG//G130/G131] in greater detail.

P-AXIS-00004

Acceleration at rapid movement (non-linear slope)

Description

This acceleration parameter is active for deceleration and acceleration with rapid traverse movements (G00).

Parameter

getriebe[i].slope_profil.a_grenz

Data type

UNS32

Data range

1 ≤ a_grenz ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in [PROG//G231] in greater detail.

P-AXIS-00005

Acceleration of step 1 in rapid mode (linear slope)

Description

The parameter defines the step 1 rapid traverse acceleration (G00). For positioning in rapid traverse (G00), ramps are often chosen steeper than for the linear and circular interpolation (G01, G02, G03).

Parameter

getriebe[i].lslope_profil.a_grenz_stufe_1

Data type

UNS32

Data range

1 ≤ a_grenz_stufe_1 ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

This limit acceleration is generally set close to the current limit to achieve fast positioning and fast deceleration values.

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in [PROG//G231] in greater detail.

P-AXIS-00006

Acceleration of step 2 in rapid mode (linear slope)

Description

The parameter defines the step 2 rapid traverse acceleration (G00). For positioning in rapid traverse (G00), ramps are often chosen steeper than for the linear and circular interpolation (G01, G02, G03).

Parameter

getriebe[i].lslope_profil.a_grenz_stufe_2

Data type

UNS32

Data range

1 ≤ a_grenz_stufe_2 ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

This limit acceleration is generally set close to the current limit to achieve fast positioning and fast deceleration values.

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in [PROG//G231] in greater detail.

P-AXIS-00008

Maximum permissible axis acceleration

Description

The parameter defines the maximum permissible axis acceleration.

Parameter

getriebe[i].dynamik.a_max

Data type

UNS32

Data range

1 ≤ a_max ≤ 100000000 (Presetting of maximum axis acceleration,

plausibility limit, application-specific)

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

 

P-AXIS-00011

Acceleration of step 1 (linear slope)

Description

The parameter only becomes active during the deceleration phases. It defines the acceleration in step 1.

Parameter

getriebe[i].lslope_profil.a_stufe_1

Data type

UNS32

Data range

1 ≤ a_stufe_1 ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R: °/s²

Default value

1000

Drive types

----

Remarks

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in detail in [PROG//G130, G131].

This parameter has no effect with spindles.

P-AXIS-00012

Acceleration of step 2 (linear slope)

Description

The parameter only becomes active during the deceleration phases. It defines the acceleration in step 2.

Parameter

getriebe[i].lslope_profil.a_stufe_2

Data type

UNS32

Data range

1 ≤ a_stufe_2 ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in detail in [PROG//G130, G131] in greater detail.

P-AXIS-00013

Weighting of acceleration at motion block transition

Description

This parameter weights the permissible acceleration at a motion block transition.

If the value 0 is not specified in the parameter list, the weighting of the permissible acceleration with the cycle time/ramp time factor is valid (default setting).

Parameter

getriebe[i].dynamik.a_trans_weight

Data type

UNS32

Data range

1 ≤ a_trans_weight ≤ 1000

Axis types

T, R, S

Dimension

T: 0.1%

R,S: 0.1%

Default value

0

Drive types

----

Remarks

This parameter is only considered if the non-linear slope is used as soon as the contour has a kink angle. To define the slope type, see

P-AXIS-00154

Weighting of jerk at block transition

Description

At the block transition from linear to circular block or vice versa, a jump in acceleration occurs, even if there is a tangential transition.

The parameter weights the permissible jerk at these types of movement transitions. Jerk is only considered if P-CHAN-00009 is set.

If P-AXIS-00154 is not set in the parameter list, the velocity is reduced to such an extent that the permissible jerk at the block transition is maintained.

Parameter

getriebe[i].dynamik.r_trans_weight

Data type

UNS32

Data range

0 ≤ r_trans_weight ≤ 1000

Axis types

T, R, S

Dimension

T: 0.1%

R,S: 0.1%

Default value

1000

Drive types

----

Remarks

This parameter is only considered if the non-linear slope is used and for circular - linear, circular - circular or linear - circular transitions.

To define the slope type, see

P-AXIS-00195

Ramp time for acceleration down-gradation (non-linear slope)

Description

The parameter defines the acceleration ramp time for the down-gradation of acceleration P-AXIS-00001.

Parameter

getriebe[i].slope_profil.tr_beschl_ab

Data type

UNS32

Data range

P-AXIS-00201 ≤ tr_beschl_ab ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

50000

drive types.

----

Remarks

The ramp time can be changed in the NC program. The appropriate NC commands are described in [PROG//Ramp time weighting (G132/G133/G134/G232/G233/G338/G339) ] in greater detail.

P-AXIS-00196

Ramp time for acceleration up-gradation (non-linear slope)

Description

The parameter defines the acceleration ramp time for the up-gradation of the acceleration P-AXIS-00001.

Parameter

getriebe[i].slope_profil.tr_beschl_zu

Data type

UNS32

Data range

P-AXIS-00201 ≤ tr_beschl_zu ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

50000

drive types.

----

Remarks

The ramp time can be changed in the NC program. The appropriate NC commands are described in [PROG//Ramp time weighting (G132/G133/G134/G232/G233/G338/G339) ] in greater detail. The default value for ramp time weighting can be defined in P-CHAN-00073.

P-AXIS-00197

Ramp time for deceleration down-gradation (non-linear slope)

Description

The parameter defines the acceleration ramp time for the down-gradation of deceleration P-AXIS-00002.

Parameter

getriebe[i].slope_profil.tr_brems_ab

Data type

UNS32

Data range

P-AXIS-00201 ≤ tr_brems_ab ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

50000

drive types.

----

Remarks

The ramp time can be changed in the NC program. The appropriate NC commands are described in [PROG//Ramp time weighting (G132/G133/G134/G232/G233/G338/G339) ] in greater detail.

P-AXIS-00198

Ramp time for deceleration up-gradation (non-linear slope)

Description

The parameter defines the acceleration ramp time for the up-gradation of deceleration P-AXIS-00002.

Parameter

getriebe[i].slope_profil.tr_brems_zu

Data type

UNS32

Data range

P-AXIS-00201 ≤ tr_brems_zu ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

50000

drive types.

----

Remarks

The ramp time can be changed in the NC program. The appropriate NC commands are described in [PROG//Ramp time weighting (G132/G133/G134/G232/G233/G338/G339) ] in greater detail.

P-AXIS-00199

Geometric ramp time

Description

The parameter defines the permissible geometric ramp time. This parameter limits axis jerk caused by the programmed contour.

Parameter

getriebe[i].dynamik.tr_geom

Data type

UNS32

Data range

0 (Preset of minimum ramp time, application-specific) ≤ tr_geom ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

10000

drive types.

----

Remarks

The ramp time can be changed in the NC program. The appropriate NC commands are described in [PROG//Ramp time weighting (G132/G133/G134/G232/G233/G338/G339)] in greater detail.

P-AXIS-00200

Ramp time at rapid movement (non-linear slope)

Description

The ramp time parameter is active with rapid traverse motions (G00) for acceleration and deceleration. In this case it replaces the 2 ramp times for acceleration (P-AXIS-00195, P-AXIS-00196) or the 2 ramp times for deceleration (P-AXIS-00197, P-AXIS-00198).

Parameter

getriebe[i].slope_profil.tr_grenz

Data type

UNS32

Data range

P-AXIS-00201 ≤ tr_grenz ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

10000

Drive types

----

Remarks

The ramp time can be changed in the NC program. The appropriate NC commands are described in detail in [PROG//G232/G233].

P-AXIS-00209

Rapid mode velocity

Description

The rapid traverse velocity is specified for positioning in rapid traverse (G00).

Parameter

getriebe[i].vb_eilgang

Data type

UNS32

Data range

1 ≤ vb_eilgang ≤ P-AXIS-00212

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

166666

Drive types

----

Remarks

 

P-AXIS-00211

Changeover speed in rapid mode (linear slope)

Description

For positioning in rapid traverse (G00), ramps are often chosen steeper than for the linear and circular interpolation (G01, G02, G03).

The parameter defines the acceleration and deceleration phases for these cases. It defines the changeover speed between step 1 and step 2 (P-AXIS-00005 and P-AXIS-00006 orP-AXIS-00281 and P-AXIS-00280).

Parameter

getriebe[i].lslope_profil.vb_grenz_stufe_1_2

Data type

UNS32

Data range

1 ≤ vb_grenz_stufe_1_2 ≤ P-AXIS-00212

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

100000

Drive types

----

Remarks

 

P-AXIS-00212

Maximum permissible axis velocity

Description

The parameter defines the maximum permissible axis velocity.

Parameter

getriebe[i].dynamik.vb_max

Data type

UNS32

Data range

1 < hb_v_max_track ≤ 2000000000 (Presetting of maximum axis velocity,

plausibility limit, application-specific)

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0,001°/s

Default value

200000

Drive types

----

Remarks

In the case of axes of the type 'ACHSTYP_TRANSLATOR' and 'ACHSTYP_ROTATOR' it is presumed that while setting the maximum permissible axis velocity the resolution limits of the measuring system will also be taken into consideration.

In the case of axes of the type 'ACHSTYP_SPINDEL' which are controlled by a spindle interpolator, the limit at which the measuring system delivers no valid values is set using the parameter P-AXIS-00220 .

 

Examples:

Spindle speed at 10000 rpm

value = 10000 * 6 * 1000 = 60000000 (unit 0.001 °/s)

With units

(10000 [rpm] * 360 [°/rev] * 1000 [0.001 °/°]) / 60 [s/min]
= 60000000 [0.001 °/s]

 

Translator at 1000 mm/min

value = 1000 * 1000 / 60 = 16666 (unit 0.001 µm/s)

With units

(1000 [rpm] * 1000 [0.001 µm/mm]) / 60 [s/min]
= 16666 [0.001 µm/s]

P-AXIS-00221

Changeover speed (linear slope)

Description

The parameter becomes active during the acceleration and deceleration phases.

It defines the changeover speed between step 1 and step 2 (P-AXIS-00011 and P-AXIS-00012 or P-AXIS-00283 and P-AXIS-00282).

Parameter

getriebe[i].lslope_profil.vb_stufe_1_2

Data type

UNS32

Data range

1 ≤ vb_stufe_1_2 ≤ P-AXIS-00212

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

100000

Drive types

----

Remarks