Overview

General dynamic characteristics

ID

Parameter

Description

P-AXIS-00008

a_max

Maximum permissible axis acceleration

P-AXIS-00209

vb_eilgang

Rapid traverse velocity

P-AXIS-00212

vb_max

Maximum permissible axis velocity

Characteristics and control flags for non-linear slope function

ID

Parameter

Description

P-AXIS-00001

a_beschl

a on acceleration

P-AXIS-00002

a_brems

a on deceleration

P-AXIS-00004

a_grenz

Rapid traverse acceleration

P-AXIS-00013

a_trans_weight

Weighting of acceleration at block transition

P-AXIS-00154

r_trans_weight

Weighting of jerk at block transition

P-AXIS-00195

tr_beschl_ab

Ramp time for acceleration down-gradation

P-AXIS-00196

tr_beschl_zu

Ramp time for acceleration up-gradation

P-AXIS-00197

tr_brems_ab

Ramp time for deceleration down-gradation

P-AXIS-00198

tr_brems_zu

Ramp time for deceleration up-gradation

P-AXIS-00199

tr_geom

Ramp time for curved contours

P-AXIS-00200

tr_grenz

Rapid traverse ramp time

ID

Parameter

Description

P-CHAN-00009

corr_v_trans_jerk

Enable jerk limitation at tangential block transitions

Characteristics for linear slope function

ID

Parameter

Description

P-AXIS-00005

a_grenz_stufe_1

Rapid traverse acceleration step 1

P-AXIS-00006

a_grenz_stufe_2

Rapid traverse acceleration step 2

P-AXIS-00011

a_stufe_1

Acceleration step 1

P-AXIS-00012

a_stufe_2

Acceleration step 2

P-AXIS-00211

vb_grenz_stufe_1_2

Rapid traverse changeover speed step 1 -> step 2

P-AXIS-00221

vb_stufe_1_2

Changeover speed step 1 -> step 2

Pre-assignment of path-specific characteristics (option)

The following parameters are effective in conjunction with path-specific commands.

ID

Parameter

Description

P-CHAN-00002

acceleration

Maximum permissible acceleration in space

P-CHAN-00090

velocity

Maximum permissible velocity in space

Effect of override

ID

Parameter

Description

P-CHAN-00066

override_weight_prog_feed

Control flag for influence of override

Default assignment of acceleration profile

ID

Parameter

Description

P-CHAN-00071

profile

Slope type

0: Step-shaped acceleration profile (default)

1: Trapezoidal acceleration profile

2: Sine-square acceleration profile

3: Trapezoidal HSC acceleration profile

Polynomials on internal B spline deselection

ID

Parameter

Description

P-CHAN-00239

hsc.bspline.auto_contour_mode

Automatic insertion of polynomials on internal B spline deselection

Enabling functionalities at start-up

ID

Parameter

Description

P-CHAN-00605

configuration.path_preparation.fct_enable