Description of flange and tool
The parameters zero_position (P-CHAN-00286) and zero_orientation (P-CHAN-00285) specify the zero position and the zero orientation of the machine.
Zero orientation of the machine
The parameter P-CHAN-00286 specifies the position of the flange in the zero orientation of the machine.
Example
Parameter definition of the flange zero position
Tool orientation in relation to zero position
The parameter P-CHAN-00285 specifies the orientation of the tool in the zero setting of the machine.
The parameter zero_orientation then only acts on the kinematic if a tool length is used. In the zero orientation of the machine, the position of the TCP is calculated as follows:
Example
Zero orientation of the tool
Example
Zero orientation of the tool at an angle of 45 degrees - with normalisation
Zero orientation must be a vector of Length 1 in order to include the tool length correctly.
Example
Zero orientation of the tool at an angle of 45 degrees - with normalisation of Length 1