KIN_TYP_16 – 5-axis kinematics

Kinematic structure

The kinematic structure consists of 3 translatory and 2 rotary NC axes in the tool.

Axis configuration in the NC channel

Axis identifier

X, Y, Z, B, A

Axis index

0, 1, 2, 3, 4

Kinematic structure

 

Tool axes

Workpiece axes

NC axes

X, Y, Z, B, A

-

KIN_TYP_16 – 5-axis kinematics 1:
Axis configuration of 5-axis machine
KIN_TYP_16 – 5-axis kinematics 2:
Parameters of rotary/swivel head

Offset data of kinematics

HD offset

param[i]

Description

Unit

HD1

0

Z offset from rotary axis A to tool fixing point

1.0 E-4 mm

HD2

1

X offset from rotary axis B to slide reference point

1.0 E-4 mm

HD3

2

Y offset from rotary axis A to slide reference point

1.0 E-4 mm

HD4

3

Z offset from rotary axis B to rotary axis A

1.0 E-4 mm

HD5

4

X offset

1.0 E-4 mm

HD6

5

Y axis offset from rotary axis A to tool

1.0 E-4 mm

HD7

6

Rotary offset A axis

1.0 E-4°

HD8

7

Rotary offset B axis

1.0 E-4°

HD9

8

Sign for direction of rotation A axis

[ - ]

HD10

9

Sign for direction of rotation B axis

[ - ]