KIN_TYP_1 – 5-axis kinematics/single-column bed machine

Kinematic structure

The kinematic structure of this machine consists of 2 translatory axes and 1 rotary axis in the workpiece as well as 1 translatory axis and 1 rotary axis in the tool.

Axis configuration in the NC channel

Axis identifier

X,Y, Z, B, C

Axis index

0, 1, 2, 3, 4

Kinematic structure

 

Tool axes

Workpiece axes

NC axes

Z, B

X, Y, C

KIN_TYP_1 – 5-axis kinematics/single-column bed machine 1:
Kinematics of the single-column bed machine
KIN_TYP_1 – 5-axis kinematics/single-column bed machine 2:
Offsets in tool head
KIN_TYP_1 – 5-axis kinematics/single-column bed machine 3:
Offsets on workpiece holder

Offset data of kinematics

HD offset

param[i]

Description

Unit

HD1

0

Z offset tool fixing point to rotation point B axis

1.0 E-4 mm

HD2

1

Z offset rotation point B axis to reference point tool slide

1.0 E-4 mm

HD3

2

X offset reference point tool slide to rotation point B axis

1.0 E-4 mm

HD4

3

Y offset reference point tool slide to rotation point B axis

1.0 E-4 mm

HD5

4

X offset rotation point B axis to tool fixing point

1.0 E-4 mm

HD6

5

Y offset rotation point B axis to tool fixing point

1.0 E-4 mm

HD7

6

X offset machine origin MNP to rotary axis C

1.0 E-4 mm

HD8

7

Y offset machine origin MNP to rotary axis C

1.0 E-4 mm

HD9

8

Z offset machine origin MNP to rotary axis C

1.0 E-4 mm

HD10

9

Rotary offset rotary axis B

1.0 E-4°

HD11

10

Rotary offset rotary axis C

1.0 E-4°

HD13

12

Rotation direction B axis (*), 0: negative, 1positive

[ - ]

HD14

13

Rotation direction C axis, 0 positive, 1 negative

[ - ]

(*) The rotation direction of the B axis is mathematically negative.