Kinematic ID and offset data - CNC Build <V300
Kinematic ID
The ID required to use a specific kinematic feature results from the specified kinematic type as follows:
KIN_TYP_1 1
KIN_TYP_2 2
etc.
Example
Specifying the kinematic ID and offset parameters
The kinematic ID and the offset parameters (HD offsets) of a kinematic are specified as follows:
kinematik[9].param[0] 500000
kinematik[9].param[1] 0
kinematik[9].param[2] 0
kinematik[9].param[3] 0
with an additional transformation, e.g. kinematic ID 60
kinematik[60].param[0] 200000
kinematik[60].param[1] 0
![]() | The HDi offsets of a kinematic correspond to the kinematic offsets in the channel parameters for kinematik[ID].param[i-1]. |
Alternatively, these offsets can be entered in the corresponding value of the tool parameters (P-TOOL-00009).
The offset parameter units are 1.0 E-4 mm for translatory offsets and 1.0 E-4° for rotary offsets.