Programming example

Programming Example

Calculation cycle

 
; creation of return variables
#VAR
  V.CYC.SysRetDirVectorX
  V.CYC.SysRetDirVectorY
  V.CYC.SysRetDirVectorZ
  V.CYC.SysRetSupVectorX
  V.CYC.SysRetSupVectorY
  V.CYC.SysRetSupVectorZ
  V.CYC.SysRetVariance
#ENDVAR
 
; calc line of X-axis from points
L CYCLE [NAME=SysCalcLine.ecy  \
@P50 = 0 @P60 = 0 @P70 = 0     \
@P51 = 1 @P61 = 0 @P71 = 0     \
@P52 = 2 @P62 = 0 @P72 = 0     \
]
 
#FILE NAME[MSG="SysCalcLineResult.txt"                   ]
#MSG SAVE ["Direction X     = %f", V.CYC.SysRetDirVectorX]
#MSG SAVE ["Direction Y     = %f", V.CYC.SysRetDirVectorY]
#MSG SAVE ["Direction Z     = %f", V.CYC.SysRetDirVectorZ]
#MSG SAVE ["Point on Line X = %f", V.CYC.SysRetSupVectorX]
#MSG SAVE ["Point on Line Y = %f", V.CYC.SysRetSupVectorY]
#MSG SAVE ["Point on Line Z = %f", V.CYC.SysRetSupVectorZ]
#MSG SAVE ["Variance        = %f", V.CYC.SysRetVariance  ]
 
M30