Parameters

Required input parameters

Cycle parameters

Description

@P6

Measurement distance in the direction of the negative Z axis, only positive values permitted [mm, inch]

@P22

Measurement offset in Z for lateral measurements [mm, inch]

Optional input parameters

Cycle parameters

Description

@P13

Safety clearance for lateral measurements [mm, inch]

Default value = 1/4 of measuring plate diameter.

@P14

Probe angle for first lateral measurement [degrees]

Default value = 0

@P15

Incremental angle for lateral measurements [degrees]

Default value = 90

@P16

Measuring feed for a slow measurement

If defined, the measurements are repeated at the specified feed rate.

@P17

Radial return clearance for the slow measurement [mm, inch]

Default value = 1

@P18

Axial return clearance for the slow measurement [mm, inch]

Default value = 1

@P20

Numbering of tool touch probe

(Required to read out the configuration from SysCalibConfigToolSettingProbe.nc)

Default value = 1

It is recommended to use the Syntax check to verify whether the input parameters are correctly assigned.