Process (internal cycle)

  1. The touch probe must be positioned manually or in automatic mode in the proximity of the front left corner so that the probe can reach all points without collision.
  2. Measurement in Z direction as follows.
  3. After the start of the cycle, the touch probe must be positioned manually above the 1st measuring point.
  4. Press Start again to start the measurement run.
  5. Repeat this process with point 2 and point 3.
  6. The orientation of the top surface is calculated.
  7. Measurements in X direction as follows.
  8. Then approach starting point 4 and press Start again.
  9. Afterwards, approach starting point 5 and press Start again.
  10. Measurements in Y as follows.
  11. Approach point 6 manually and press Start.
  12. Finally, approach point 7 manually and press Start.
  13. The orientation about the Z axis is calculated using points 4 to 7.
  14. A new file is written CS_BASE_[CS ID @P39].bcs

Notice

If the file already exists, it is deleted and a new file is written. No back-up is made!