General
A axis is the designation for the rotary axis about X.
B axis is the designation for the rotary axis about Y.
C axis is the designation for the rotary axis about Z.
![]() | The SysCalibConfigTouchprobe.nc file is not used for manual teach-in. |
If no measuring signal is triggered during the measurement, the machine stops with the error message: “No workpiece detected, please check your measuring section.“
P-ERR-13413
If a measurement is detected during positioning, the machine stops with the error message: “Collision on positioning, please check your motion range.“
P-ERR-13414
The SysCalibConfigTouchprobe.nc file must be present and configured before the cycles are used, otherwise the cycles cannot run.
At the end of the cycles, a file is written CS_BASE_[CS ID @P39].bcs.
Notice | |
If the file already exists, it is deleted and a new file is written. No back-up is made! |
From then on, the file can be called from any program.
The generated program defines the required coordinate system (CS) and enables it immediately.