Programming example
Programming Example
Inner diameter with 4 points
; touch probe activation
T1 D1
; deactivation of the zero offset
G53
; positioning to the starting point
G0 X0 Y0
G0 Z-10
#VAR
;input parameters
V.L.HoleDiameter = 40
V.L.ZeroOffsetNumber = 54
V.L.SafetyDistance = 5
V.L.CrossOver = 10
;output variables
V.CYC.SysRetX
V.CYC.SysRetY
V.CYC.SysRetDiameter
#ENDVAR
;cycle call
L CYCLE [NAME="SysMeasWcs8.ecy" \
@P2=V.L.HoleDiameter \
@P7=V.L.ZeroOffsetNumber \
@P13=V.L.SafetyDistance \
@P33=V.L.CrossOver ]
; print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetX =%f", V.CYC.SysRetX ]
#MSG SAVE ["V.CYC.SysRetY =%f", V.CYC.SysRetY ]
#MSG SAVE ["V.CYC.SysRetDiameter =%f", V.CYC.SysRetDiameter]
G0 Z10
M30
Another example for handling SysMeasWcs cycles is contained in the Overview section in the subsection Programming.