Programming example

Programming Example

Centre point across 4 drilled holes

; touch probe activation
T1 D1
 
; deactivation of the zero offset
G53
 
; positioning to the starting point
G0 X0 Y0 Z5
 
#VAR
  ;input parameters
  V.L.HoleDiameter     = 30
  V.L.ZeroOffsetNumber = 54
  V.L.SafetyDistance   = 5
  V.L.PositioningX     = 40
  V.L.PositioningY     = 30
  V.L.PositioningZ     = -15
  V.L.CrossOver        = 10
 
  ;output variables
  V.CYC.SysRetX
  V.CYC.SysRetY
#ENDVAR
 
;cycle call
L CYCLE [NAME="SysMeasWcs30.ecy"  \
        @P2=V.L.HoleDiameter    \
        @P7=V.L.ZeroOffsetNumber\
        @P13=V.L.SafetyDistance \
        @P17=V.L.PositioningX   \
        @P18=V.L.PositioningY   \
        @P19=V.L.PositioningZ   \
        @P33=V.L.CrossOver      ]
 
; print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetX =%f", V.CYC.SysRetX]
#MSG SAVE ["V.CYC.SysRetY =%f", V.CYC.SysRetY]
 
M30

Another example for handling SysMeasWcs cycles is contained in the Overview section in the subsection Programming.