Programming example

Programming Example

Measure angle between point in Y and spigot (C axis)

; touch probe activation
T1 D1
 
; deactivation of the zero offset
G53
 
; positioning to the starting point
G0 X0 Y0 Z5
 
#VAR
  ;input parameters
  V.L.SpigotDiameter   = 20
  V.L.MeasDistX        = 10
  V.L.ZeroOffsetNumber = 54
  V.L.SafetyDistance   = 10
  V.L.PositioningX     = 50
  V.L.PositioningY     = 20
  V.L.PositioningZ     = -15
  V.L.MeasDepth        = -10
  V.L.CrossOver        = 10
 
  ;output variables
  V.CYC.SysRetC
#ENDVAR
 
;cycle call
L CYCLE [NAME="SysMeasWcs25.ecy"   \
        @P2=V.L.SpigotDiameter   \
        @P4=V.L.MeasDistX        \
        @P7=V.L.ZeroOffsetNumber \
        @P13=V.L.SafetyDistance  \
        @P17=V.L.PositioningX    \
        @P18=V.L.PositioningY    \
        @P19=V.L.PositioningZ    \
        @P22=V.L.MeasDepth       \
        @P33=V.L.CrossOver       ]
 
; print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetC =%f", V.CYC.SysRetC]
 
M30

Another example for handling SysMeasWcs cycles is contained in the Overview section in the subsection Programming.