Programming example
Programming Example
Measure angle between point in Y and drilled hole (C axis)
; touch probe activation
T1 D1
; deactivation of the zero offset
G53
; positioning to the starting point
G0 X0 Y0 Z5
#VAR
  ;input parameters
  V.L.HoleDiameter     = 20
  V.L.MeasDistX        = 10
  V.L.ZeroOffsetNumber = 54
  V.L.PositioningX     = 50
  V.L.PositioningY     = 20
  V.L.PositioningZ     = 10
  V.L.MeasDepth        = -10
  V.L.CrossOver        = 10
  ;output variables
  V.CYC.SysRetC
#ENDVAR
;cycle call
L CYCLE [NAME="SysMeasWcs24.ecy"     \
          @P2=V.L.HoleDiameter     \
          @P4=V.L.MeasDistX        \
          @P7=V.L.ZeroOffsetNumber \
          @P17=V.L.PositioningX    \
          @P18=V.L.PositioningY    \
          @P19=V.L.PositioningZ    \
          @P22=V.L.MeasDepth       \
          @P33=V.L.CrossOver       ]
; print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetC =%f", V.CYC.SysRetC]
M30
Another example for handling SysMeasWcs cycles is contained in the Overview section in the subsection Programming.