Programming example

Programming Example

Measure angle in Y axis (C axis)

; touch probe activation
T1 D1
 
; deactivation of the zero offset
G53
 
; positioning to the starting point
G0 X0 Y0
G0 Z5
 
#VAR
  ;input parameters
  V.L.MeasDistY        = 10
  V.L.ZeroOffsetNumber = 54
  V.L.PositioningX     = 10
  V.L.PrePosZ          = 5
  V.L.StartPrePosZ     = -15
 
  ;output variables
  V.CYC.SysRetC
#ENDVAR
 
;cycle call
L CYCLE [NAME="SysMeasWcs20.ecy"\
        @P5=V.L.MeasDistY\
        @P7=V.L.ZeroOffsetNumber\
        @P17=V.L.PositioningX\
        @P19=V.L.PrePosZ\
        @P20=V.L.StartPrePosZ]
 
; print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetC =%f", V.CYC.SysRetC]
 
G0 Z10
 
M30

Another example for handling SysMeasWcs cycles is contained in the Overview section in the subsection Programming.