Programming example

Programming Example

Measure angle in X axis (C axis)

; touch probe activation
T1 D1
 
; deactivation of the zero offset
G53
 
; positioning to the starting point
G0 X0 Y0
G0 Z5
 
#VAR
  ;input parameters
  V.L.MeasDistX        = 10
  V.L.ZeroOffsetNumber = 54
  V.L.TargetAngle      = 15
  V.L.PositioningY     = 10
  V.L.PrePosZ          = 5
  V.L.StartPrePosZ     = -15
 
  ;output variables
  V.CYC.SysRetC
#ENDVAR
 
; Using zero offset
 
;cycle call
L CYCLE [NAME="SysMeasWcs19.ecy"   \
        @P4  = V.L.MeasDistX       \
        @P7  = V.L.ZeroOffsetNumber\
        @P12 = V.L.TargetAngle     \
        @P18 = V.L.PositioningY    \
        @P19 = V.L.PrePosZ         \
        @P20 = V.L.StartPrePosZ    ]
 
 
;print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetC =%f", V.CYC.SysRetC]
 
;GV.L.ZeroOffsetNumber
;G00 C0
;:
M30
 
 
;set #CS rotation about the Z axis
 
;cycle call
L CYCLE [NAME="SysMeasWcs19.ecy"   \
        @P4  = V.L.MeasDistX       \
        @P18 = V.L.PositioningY    \
        @P19 = V.L.PrePosZ         \
        @P20 = V.L.StartPrePosZ    ]
 
;print result
#FILE NAME [MSG="SysMeasWcsResult.txt"]
#MSG SAVE ["V.CYC.SysRetC =%f", V.CYC.SysRetC]
 
#CS ON [0,0,0,0,0,V.CYC.SysRetC]
;:
#CS Off
 
M30

Another example for handling SysMeasWcs cycles is contained in the Overview section in the subsection Programming.