Parameters
The touch probe must be configured in addition to supplying the input parameters described here. For more information on this function, see the section Configuration file.
The (calibrated) parameters of the touch probe (radius, length and offset in X and Y directions) are specified via the tool parameters.
Required input parameters
Input parameters | Description |
@P3 | Slot width |
Optional input parameters
Input parameters | Description |
@P7 | Zero offset to be described (TCS) G159=1 to G159=9 and G54 to G59 Input without address "G159=" or "G" If not specified, then measurement only but no write function Only permitted when G53 is active at cycle call. |
@P9 | Shift the measuring point along the X axis |
@P13 | Safety clearance for pre-positioning If @P13 is not specified, the entire measuring section is traversed at the measuring feed |
@P33 | Crossover range (unsigned) [mm, inch] Additional motion path that exceeds the expected workpiece edge/workpiece surface Default value = 5 |
It is recommended to use the Syntax check to verify whether the input parameters are correctly assigned.
Logging
The logging function is enabled for this cycle.