Overview
![]() | This function is an additional option requiring a license. |
Task
Vibrations in a machine tool can have a negative impact on machining results. A particularly critical factor is the natural frequency of the machine or frequencies caused by the machining program which may lead to an excitation of the machine.
The Vibration Guard function permits the following:
- the specific smoothing of setpoint curves at axis level to minimise or prevent critical excitation
- specifying a maximum permitted tolerance to limit contour deviations caused by setpoint smoothing
![]() | This function is available as of CNC Build V3.1.3075.02 |
Programming and parametrisation
Parameter settings and function activation can take place
- either in axis lists or
- by using the programming command #VIB GUARD in the NC program.
Mandatory note on references to other documents
For the sake of clarity, links to other documents and parameters are abbreviated, e.g. [PROG] for the Programming Manual or P-AXIS-00001 for an axis parameter.
For technical reasons, these links only function in the Online Help (HTML5, CHM) but not in pdf files since pdfs do not support cross-linking.