Overview
Task
The aim of this functionality is to reduce machine oscillations caused by frequent program-related acceleration and deceleration processes. The functionality smooths the planned path velocity curve while taking a predefined criterion into consideration.
Effectiveness
Smoothing the path velocity curve or reducing acceleration and deceleration processes is achieved by cross-block adjustment of the planned maximum path velocities. The maximum path velocities are adjusted by reducing them, which can result in a longer machining time.
Specifying the smoothing criterion (productivity factor) defines
- the degree of smoothing as well as
- the maximum machining time that is tolerable.
![]() | This functionality is available as of CNC Build V3.01.3079.21. |
Parameterisation
In order to use this functionality, it must be enabled by the parameter P-CHAN-00600.
Programming
The functionality is parameterised by the NC command #LAH[…].