Thread chain

Before a thread cutting block, synchronisation normally takes place with the spindle axis involved in the cutting process. The thread chain function allows multiple thread cutting blocks to be strung together. They are then processed together on the path without motion stop.

Thread chain 1:
Thread chain

This function is available as of V3.1.3081.11 or V3.1.3118.0

The function is activated either by P-CHAN-00837 or by the NC command #TURN[THREAD_CHAIN=1].

Notice

Any override changes in a thread chain are ineffective.

Programming Example

Thread chain with 5 thread cutting blocks

%Thread_chain
N010 G74 S1
N020 M03 S2000
N030 G90 G51
N040 #TURN [THREAD_CHAIN = 1]
N050 G0 X100 Z0 Z500
N060 G33 Z100  K5
N070 G33 Z200 X140
N080 G33 Z300
N090 G33 Z350 X100
N100 G33 Z450  K7.5
N110 G0 Z500
N120 M05
N130 M30
Thread chain 2:
Thread chain with 5 thread cutting blocks