Defining the functionalities for path preparation (P-STUP-00060)

P-STUP-00060

Defining functionalities for path preparation.

Description

This parameter defines the individual functionalities for path preparation. The individual functions can be enabled or disabled for testing or for performance reasons.

Parameter

configuration.channel[i].path_preparation.function

Data type

STRING

Data range

See Defining the functionalities for path preparation (P-STUP-00060)

Dimension

----

Default value

FCT_DEFAULT

Remarks

 

Path preparation function table

Identifier

Description

FCT_DEFAULT

The functions FCT_FFM | FCT_PRESEGMENTATION | FCT_SPLINE | FCT_POLY | FCT_CAX | FCT_CAX_TRACK | FCT_SEGMENTATION are available.

FCT_FFM

Free-form surface mode, #HSC [OPMODE 1 CONTERR 0.01], #HSC [OPMODE 2]

FCT_PRESEGMENTATION

Linear pre-segmentation in HSC mode

FCT_SPLINE

#HSC[], AKIMA, B-Spline, G150/G151

FCT_POLY

#CONTOUR MODE[], G61, G261/G260

FCT_CAX

C axis processing, i.e. the spindle is embedded in the NC channel.

FCT_CAX_TRACK

#CAXTRACK, tracking an axis according to the contour angle

FCT_SEGMENTATION

For dynamic segmentation of the path contour, e.g. if the curvature of a polynomial segment varies significantly.

The following functions must also be enabled:

FCT_LIFT_UP

Automatic lifting/lowering of an axis (path-based coupling).
Example: FCT_DEFAULT | FCT_LIFT_UP

FCT_EMF

Edge machining (sharp angle contours).
Example: FCT_DEFAULT | FCT_EMF

FCT_EMF_POLY_OFF

Edge machining inactive with polynomials.

Contrary to the setting with FCT_EMF, edge signal generation is masked when path polynomial generation is active in the channel. Polynomials are generated for smoothing G261 or when B Spline is active. The resulting geometry is then tangential.

Example: FCT_DEFAULT | FCT_EMF_POLY_OFF

FCT_SYNC

Synchronise an axis to a path group.
Example: FCT_DEFAULT | FCT_SYNC

FCT_PRECON

Optimised planning using #HSC[BSPLINE].
Example: FCT_DEFAULT | FCT_PRECON

FCT_LIFT_UP_TIME

Automatic lifting/lowering of an axis (time-based coupling).
Example: FCT_DEFAULT | FCT_LIFT_UP_TIME

FCT_PTP

Dynamically optimised smoothing of the complete contour (linear motions only).
Example: FCT_DEFAULT | FCT_PTP

FCT_PTP_CIR

Dynamically optimised smoothing of the complete contour (linear and circular motions).
as of Build V3.1.3143.0
Example: FCT_DEFAULT | FCT_PTP_CIR

FCT_POSTSEG

Segmenting before splining
as of V3.1.3080.8 and V3.1.3107.41
Example: FCT_DEFAULT | FCT_POSTSEG

FCT_M_PRE_OUTPUT

Pre-output of M/H functions (microjoints).
Example: FCT_DEFAULT | FCT_M_PRE_OUTPUT

FCT_SURFACE

HSC machining with Surface Optimiser
Example: FCT_DEFAULT | FCT_SURFACE

FCT_SEG_CHECK

Block segmentation in combination with path-controlled offset of M functions (dwell time),
See P-CHAN-00650 and Interpolation function table
Example: FCT_DEFAULT | FCT_SEG_CHECK

FCT_NIBBLING

Activate the nibbling function
Example: FCT_DEFAULT | FCT_NIBBLING

FCT_PUNCHING

Activate the punching function
Example: FCT_DEFAULT | FCT_PUNCHING

FCT_VSM

Activate the velocity smoothing function
Example: FCT_DEFAULT | FCT_VSM
as of V3.1.3079.21